Detail SICK Fiber-optic Sensors WLL260, Fiber-optic Photoelectric Sensor
SICK Fiber-optic sensors WLL260, Fiber-optic photoelectric sensor
Model Name WLL260-E240
Part No. 6020063
At a glance
Fiber-optic cable for proximity version
Fiber-optic cable for through-beam version
Mounting bracket is included
Light/ dark switching
M12 connector or easily accessible terminal connection compartment
Models for 10 - 30 V DC or 12 - 240 V DC/ 24 – 240 V AC voltage supply
Your benefits
A diverse range of fiber-optic cables provide reliable detection of objects, even in the tightest of spaces
Controls are protected under a cover, reducing tampering
Easily accessible terminal connection compartment simplifies electrical connection
Assembly compatibility - DC devices and DC/ AC devices available in the same design
Features
Dimensions ( W x H x D) : 25 mm x 77.8 mm x 63 mm
Sensing range max.: 0 mm ... 110 mm, proximity system, 0 mm ... 65 mm, proximity system, 0 mm ... 800 mm, through-beam system 1) 2) 3) 4) 5)
Sensing range: 0 mm ... 50 mm, proximity system, 0 mm ... 700 mm, through-beam system, 0 mm ... 90 mm, proximity system 6) 7) 8)
Light source: LED 9)
Type of light: Visible red light
Sensitivity adjustment: Potentiometer, 270°
Indication: LED
Light spot diameter ( distance) : Depends on scanning range
Sensor/ detection principle: Fiber-optic photoelectric sensor
Housing design ( light emission) : Rectangular
1) 3) Object with 90 % reflectance ( referred to standard white DIN 5033) 2) 5) 6) 8) LIS/ LIB 4) 7) With special fibre-optic cable 9) Average service life of 100, 000 h at TA = + 25 ° C
Mechanics/ electronics
Enclosure rating: IP 66
Supply voltage: 10 V DC ... 30 V DC 1)
Ripple: d 5 Vpp 2)
Power consumption: d 35 mA 3)
Output type: NPN, Light/ dark-switching, selectable via light/ dark selector, open collector
Output current Imax.: 100 mA
Response time: d 0.7 ms 4)
Switching frequency: 700 Hz 5)
Connection type: Cable gland
Protection class: II 6)
Circuit protection: A, B, C, D 7) 8) 9) 10)
Housing material: ABS
Ambient operating temperature: -25 ° C ... 55 ° C
Ambient storage temperature: -40 ° C ... 70 ° C
Weight: 120 g
Items supplied: Mounting bracket BEF-W260
Test input sender off: TE to 0 V
UL File-No.: UL No. NRNT2.E128350 & cUL No. NRNT8.E128350
1) Limit values, operation in short-circuit protected network max. 8 A 2) May not exceed or fall short of VS tolerances 3) Without load 4) Signal transit time with resistive load 5) With light/ dark ratio 1: 1 6) Reference voltage 50 V DC 7) A = VS connections reverse-polarity protected 8) B = inputs and output reverse-polarity protected 9) C = interference suppression 10) D = outputs overcurrent and short-circuit protected
Tampilkan Lebih Banyak