Detail ASAHI KEIKI Universal Isolate Transducer MODEL TW-4M-1-N, TW-4M-4-N
ASAHI KEIKI Universal Isolate transducer MODEL TW-4M-1-N, TW-4M-4-N
> General Specifi cations
1. Range settings before shipment:
Input; 1 to 5 VDC, output;
4 to 20 mADC
Accuracy of range settings before
shipment: Within ± 0.25% F.S
2. Error caused by input range setting
change: Within ± 1% F.S Error caused
by output range setting change: Within
± 1% F.S
3. Temperature characteristic: ± 0.02%
F.S/ ° C
4. Response time: Less than 50ms ( Time
required for arriving at 90% of rated
output)
5. Insulation resistance: Between input
and output or power supply, More than
100 M© ( At 500 VDC)
6. Dielectric strength: Between input and
output or power supply, For 1 min. ( At
2000 VAC)
7. Power supply voltage: 100 to 240
VAC ± 10% or 24 VDC ± 10%
Consuming current:
Less than 50mA ( At 100 VAC)
Less than 80mA ( At 24 VDC)
8. Operating ambient temperature: -5 to
+ 50° C
9. Operating humidity: Less than 90% RH
( No dew-condensing)
10. Storage temperature: -10 to + 70° C
11. Storage humidity: Less than 60% RH
( No dew-condensing)
12. Case material: Black PBT 94-V0
13. Weight: Approx. 130g
Tampilkan Lebih Banyak