Detail OMRON Digital Panel Meter K3TE Series
OMRON Digital Panel Meter K3TE Series
Easy-to-use, Low-cost Digital Panel Meter
that Accepts DC Input
? Compact DIN-size ( 96 x 48 ( W x H) ) body.
? Mounting thickness of only 3.5 mm required.
? Highly visible display with 14.2-mm-high LEDs.
? Easy-to-mount snap-in construction.
? Conforms to EMC standards EN61010-1 ( IEC61010-1) .
Specifications
? Ratings
Note: 1. An inrush current of approximately 0.5 A will flow at the moment the power is turned on and continued for approximately 2 ms.
2. The K3TE-V4@ @ does not conform to CE marking standards.
? Characteristics
Note: IP51 is maintained when the water-resistive soft cover and bracket are used. IP50 will be, however, maintained without these water-resistive
accessories.
Supply voltage 100 to 120 VAC; 200 to 240 VAC ( 50/ 60 Hz) ; 24 VDC ( internally insulated)
Operating voltage range 15% to + 10% of supply voltage
Power consumption 3 VA ( at max. AC load) ; 1.3 W ( at max. DC load) ( see note)
Insulation resistance 10 M min. ( at 500 VDC) between external terminal and case
Dielectric strength AC model: 2, 000 VAC min. for 1 min between input terminal and power supply
DC model: 500 VDC min. for 1 min between input terminal and power supply
AC/ DC model: 2, 000 VAC min. for 1 min between external terminal and case
Noise immunity AC model: 1, 500 V on power supply terminals in normal or common mode
DC model: 480 V on power supply terminals in normal mode
1, 500 V on power supply terminals in common mode
Vibration resistance Malfunction: 10 to 55 Hz, 0.5-mm single amplitude for 10 min each in X, Y, and Z directions
Destruction: 10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in X, Y, and Z directions
Shock resistance Malfunction: 98 m/ s2 for 3 times each in 6 directions
Destruction: 294 m/ s2 for 3 times each in 6 directions
Ambient temperature Operating: 10 to 55 C ( with no icing)
Storage: 20 to 65 C ( with no icing)
Ambient humidity Operating: 35% to 85% ( with no condensation)
Ambient operating atmosphere No corrosive gas
EMC ( EMI) EN61326+ A1 Industry
Emission Enclosure: CISPR 11 Group 1 class A: CISRP16-1/ -2
Emission AC Mains: CISPR 11 Group 1 class A: CISRP16-1/ -2
( EMS) EN61326+ A1 Industry
Immunity ESD: EN61000-4-2: 4 kV contact discharge ( level 2)
8 kV air discharge ( level 3)
Immunity RF-interference: EN61000-4-3: 10 V/ m ( amplitude-modulated,
80 MHz to 1 GHz) ( level 3)
Immunity Fast Transient Noise: EN61000-4-4: 2 kV ( power line) ( level 3)
Immunity Burst Noise: 1 kV line to line ( I/ O signal line)
Immunity Surge: EN61000-4-5: 1 kV line to line
2 kV line to ground ( power line)
Immunity Conducted Disturbance EN61000-4-6: 3 V ( 0.15 to 80 MHz) ( level 2)
Immunity Voltage Dip/ Interrupting EN61000-4-11: 0.5 cycles, 0, 180 , 100% ( rated voltage)
Approved standards Conforms to EN61326+ A1, EN61010-1 ( IEC61010-1)
Conforms to VDE0106/ P100 ( finger protection) when the terminal cover is mounted.
Tampilkan Lebih Banyak