Detail OMRON Rotary Pulse Indicator K3HB-R Series
OMRON Rotary Pulse Indicator K3HB-R Series
Digital Rotary Pulse Meter Capable of 50 kHz Measurements
? Visual confirmation of judgement results through display colors that
switch between red and green. * 1
? Measures High-speed Pulses at 50 kHz.
Provides high-speed pulse measurements up to 50 kHz of rotary encoder or ON/ OFF
pulse signals and can perform rotating measurement of high-speed rotating objects.
Note: No-voltage contacts of up to 30 Hz are supported.
? Six Measurement Operations Including Rotation ( rpm) / Circumferential
Speed, Ratio, and Cumulative
One Rotary Pulse Meter has 6 rotary pulse measurement functions to support a
variety of pulse measurement applications. Select the best function for your
application from the following: Rotation ( rpm) / circumferential speed/ instantaneous
flowrate ( value proportional to frequency) , absolute ratio, error ratio, error, flow rate
ratio, and passing speed ( value inversely proportional to frequency) .
Specifications
? Ratings
Note: 1. DC power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned ON. Particular
attention is required when using two or more DC power supply models. The OMRON S8VS-series DC Power Supply Unit is
recommended.
2. PNP input types are also available.
3. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for
Thin Cables.
Supply voltage 100 to 240 VAC, 24 VAC/ VDC, DeviceNet power supply: 24 VDC
Allowable power supply voltage
range
85% to 110% of the rated power supply voltage, DeviceNet power supply: 11 to 25 VDC
Power consumption
( See note 1.)
100 to 240 VAC: 18 VA max. ( max. load)
24 VAC/ DC: 11 VA/ 7 W max. ( max. load)
Current consumption DeviceNet power supply: 50 mA max. ( 24 VDC)
Input No-voltage contact, voltage pulse, open collector
External power supply 12 VDC 10% , 80 mA ( models with external power supply only)
Event inputs
( See note 2.)
Startup compensation
timer input
NPN open collector or no-voltage contact signal
ON residual voltage: 2 V max.
ON current at 0 : 4 mA max.
Max. applied voltage: 30 VDC max.
OFF leakage current: 0.1 mA max.
Hold input
Reset input
Bank input
Output ratings
( depends on
the model)
Relay output 250 VAC, 30 VDC, 5 A ( resistive load)
Mechanical life expectancy: 5, 000, 000 operations, Electrical life expectancy: 100, 000 operations
Transistor output Maximum load voltage: 24 VDC, Maximum load current: 50 mA, Leakage current: 100 A max.
Linear output Linear output 0 to 20 mA DC, 4 to 20 mA DC:
Load: 500 max, Resolution: Approx. 10, 000, Output error: 0.5% FS
Linear output 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC:
Load: 5 k max, Resolution: Approx. 10, 000, Output error: 0.5% FS
( 1 V or less: 0.15 V; no output for 0 V or less)
Display method Negative LCD ( backlit LED) display
7-segment digital display ( Character height: PV: 14.2 mm ( green/ red) ; SV: 4.9 mm ( green) )
Main functions Scaling function, measurement operation selection, averaging, output hysteresis, output OFF delay, output test,
teaching, display value selection, display color selection, key protection, bank selection, display refresh period, maximum/
minimum hold, reset
Ambient operating temperature 10 to 55 C ( with no icing or condensation)
Ambient operating humidity 25% to 85%
Storage temperature 25 to 65 C ( with no icing or condensation)
Altitude 2, 000 m max.
Accessories Watertight packing, 2 fixtures, terminal cover, unit stickers, instruction manual. DeviceNet models also include a DeviceNet
connector ( Hirose HR31-5.08P-5SC( 01) ) and crimp terminals ( Hirose HR31-SC-121) ( See note 3.)