Detail SICK Photoelectric Sensors W15, Photoelectric Retro-reflective Sensor, Standard Optics
SICK Photoelectric sensors W15, Photoelectric retro-reflective sensor, Standard optics
Model Name WL15-A1130
Part No. 1046279
At a glance
Photoelectric retro-reflective sensor in hybrid design with 5 m sensing range
Mounting flexibility: M18 front mount using plastic nut or snap ring, side assembly with 24.1 mm through holes
Flush mounting possible using the snap ring
Transparent back cover
Highly visible sender LED
Options with an adjustable delay of 0 - 2s
Your benefits
Compatible with many competitor models, making it easy to install and commission
Flush mounting reduces setup time and prevents obstructions to material flow on conveyor sections
Clearly visible LED indicators reduce setup time and simplify troubleshooting
Quick and easy alignment due to highly visible light spot
Features
Sensor/ detection principle: Photoelectric retro-reflective sensor, Standard optics
Dimensions ( W x H x D) : 16.2 mm x 48.5 mm x 31.9 mm
Housing design ( light emission) : Hybrid
Thread diameter ( housing) : M18 x 1
Sensing range max.: 0.035 m ... 5 m 1)
Sensing range: 0.035 m ... 3.5 m
Type of light: Visible red light
Light source: LED 2)
Wave length: 650 nm
Angle of dispersion: 1.5 °
Light spot size ( distance) : 140 mm ( 3.5 m)
1) PL80A 2) Average service life of 100, 000 h at TA = + 25 ° C
Mechanics/ electronics
Supply voltage: 10 V DC ... 30 V DC 1)
Ripple: d 5 Vpp 2)
Power consumption: d 30 mA 3)
Output type: NPN, PNP
Switching mode: Dark switching
Output current Imax.: d 100 mA
Response time: d 1.25 ms 4)
Switching frequency: 400 Hz 5)
Connection type: Cable, 4-wire, 2 m 6)
Cable material: PUR
Conductor cross-section: 0.14 mm²
Circuit protection: A, B, D 7) 8) 9)
Protection class: II 10)
Weight: 20 g
Polarisation filter:
Housing material: ABS, Plastic
Optics material: PMMA
Enclosure rating: IP 67
Items supplied: Snap-ring and M18 nut
Ambient operating temperature: -25 ° C ... 55 ° C
Ambient storage temperature: -25 ° C ... 70 ° C
UL File No.: NRKH7.E189383
1) Limit values, operation in short-circuit protected network max. 8 A 2) May not exceed or fall short of VS tolerances 3) Without load 4) Signal transit time with resistive load 5) With light/ dark ratio 1: 1 6) Do not bend below 0 ° C 7) A = VS connections reverse-polarity protected 8) B = inputs and output reverse-polarity protected 9) D = outputs overcurrent and short-circuit protected 10) Reference voltage 50 V DC
Tampilkan Lebih Banyak